01 / SPECIFICATIONS
Technical specifications
| Membrane | LPV I: single hydrophilic PVDF layer; LPV II: dual hydrophilic PVDF layers |
|---|---|
| Support layer | PP |
| Cage / core / end caps | PP |
| Outer diameter | 69 mm |
| Lengths | 5 / 10 / 20 / 30 / 40 in |
| Pore-size options | LPV I: 0.1 / 0.22 / 0.65 μm; LPV II: 0.22+0.22 / 0.45+0.45 / 0.65+0.45 μm |
| Maximum operating temperature | 80 °C |
| Maximum forward differential pressure | 0.69 MPa @ 25 °C; 0.40 MPa @ 60 °C; 0.24 MPa @ 80 °C |
| Maximum reverse differential pressure | 0.30 MPa @ 25 °C; 0.10 MPa @ 80 °C |
| End connections | DOE / 222 fin / 226 fin / 222 flat / 226 flat / 215 flat |
| Steam-in-place conditions | 135 °C / 30 min / 50 cycles; ΔP < 30 kPa |
02 / FEATURES
Key features
- Single- and dual-layer configurations
- Water-wet integrity-test limits are provided
03 / APPLICATIONS
Applications
Selection notes
- Sterilizing applications require process validation with the actual fluid, sterilization procedure and integrity test.
- Some pore-size codes differ in print. Only unambiguous options are listed; confirm the complete configuration against a controlled ordering specification.