01 / SPECIFICATIONS
Technical specifications
| Membrane / medium | Hydrophobic / hydrophilic PTFE |
|---|---|
| Support / drainage | PFA |
| End caps / cage / core | PFA |
| Maximum operating temperature | 180 °C |
| Filtration area | 0.91 / 1.21 m² per 10 in and other configurations |
| Maximum forward differential pressure | 0.42 MPa (temperature not stated) |
| Maximum reverse differential pressure | 0.21 MPa (temperature not stated) |
| Filtration ratings | 0.02 / 0.03 / 0.05 / 0.10 / 0.22 / 0.45 / 10 μm |
| Seals | EPDM / FKM / silicone / fluoropolymer-encapsulated |
02 / FEATURES
Key features
- Offered in Φ56, Φ69 and Φ83 series
- Dry and pre-wetted packaging options
03 / APPLICATIONS
Applications
Selection notes
- Temperature and pressure limits are listed separately in the source; do not assume they can be reached simultaneously. Confirm the selected configuration against its controlled data sheet.
- The Φ56 series is limited to 2.5 / 5 in and 116 O-ring configurations.