01 / SPECIFICATIONS
Technical specifications
| Membrane / medium | PP / glass fiber |
|---|---|
| Diameter | HFP/HFH: 152 mm; HFM: 165 mm |
| Maximum operating temperature | 80 °C |
| Maximum differential pressure | 0.3 MPa @ 60 °C |
| Construction | Single open end; HFP uses inside-to-outside flow |
| Published flow | HFP/HFPH: up to 70 m³/h (40 in); HFM/HFMH: up to 80 m³/h; HFH/HFHH: up to 70 m³/h |
02 / FEATURES
Key features
- HFP / HFH families have a 152 mm diameter
- HFM family has a 165 mm diameter
03 / APPLICATIONS
Applications
Selection notes
- Temperature and pressure limits are listed separately in the source; do not assume they can be reached simultaneously. Confirm the selected configuration against its controlled data sheet.
- The published flow figures do not state fluid, differential pressure or temperature and are not guarantees for a specific duty.
- Photo shows the source HFP / HFPH family; consult the source page for other end configurations.